High-Performance SY-9100 Liquid Chromatograph from China Suppliers and Factory for Reliable Quality Control and Analysis
Product Video
Features
High Pressure Pump
- The solvent management system integrates the solvent and the tray, so that it easily expands the binary gradient system from 2 mobile phase to 4 mobile phases.
- The new solvent management system easily solves the daily tedious problems of mobile phase replacement and system cleaning and maintenance when using binary high-pressure gradient system, and reduce the burden of laboratory personnel.
- With the inherent advantages of the binary high-pressure gradient, the analysis requirements of sample diversification can be easily fulfilled.
- Through the time program setting of the chromatography workstation software, it is easy to realize any combination and switch of the four mobile phases, which is convenient to change the mobile phase and flush the system after the detection of different samples.
- This could provide convenient and excellent experience for users.
Autosampler
- Different injection modes and precise metering pump design ensure the excellent injection accuracy and long-term stability of data-analysis.
- Maintenance-free mechanical structure provides longer lifetime.
- The sample injection range is from 0.1 to 1000 μL, which ensures the high precision sampling of both large and small volume samples (the standard configuration is 0.1~100 μL).
- The short sampling cycle and the high repetitive sampling efficiency lead to quick and efficient repetitive sampling, so as to save time.
- The inner wall of the sample needle can be cleaned inside the autosampler, that is the sample needle flushing mouth can wash the outer surface of the sample needle to ensure very low cross contamination.
- Optional sample chamber refrigeration provides cooling and heating in the range of 4-40°C for biological and medical samples.
- The independent control software can match the liquid chromatography system of many manufacturers on the market.
High Pressure Pump
- Advanced electronic pulse compensation is adopted to reduce the dead volume of the system and ensure the repeatability of the measurement results.
- The one-way valve, seal ring, and plunger rod are imported parts to ensure the durability of the pump.
- The multi-point flow correction curve to ensures the flow accuracy within the full flow range.
- The independent pump head is easier to be installed and disassembled.
- Floating plunger design ensures higher lifetime of the seal ring.
- Open-source computer communication protocol is easy controlled by third-party software.
UV-Vis Detector
- The dual-wavelength detector can detect two different wavelengths at the same time, which meet requirements of different wavelength detection items in the same sample simultaneously.
- The detector adopts imported grating with high precision and imported light source with long lifetime and short stability time.
- Wavelength positioning uses advanced high-precision stepper motor (imported from the United States) which directly control the wavelength to achieve great accuracy and reproducibility.
- In a high precision data acquisition chip, the acquisition terminal directly converts analog signal into digital signal, which avoids interference in the transmission process.
- The open communication protocol of detector is accessible for third-party software. At the same time, the optional analog acquisition circuit is compatible with other domestic chromatography software.
Column Oven
- The column temperature control system adopts international advanced processing chip to ensure high precision and high stability.
- Independent double column design is suitable for various specifications of chromatographic columns.
- The high sensitivity sensor achieves the high accuracy of system temperature control.
- Overtemperature protection function makes the column oven safe and reliable.
- Automatic switch between the double columns (optional).
Chromatography Workstation
- Workstation software can fully control all unit components (except some special detectors).
- Adopts database structure, which has one-key data backup and restore function, to ensure data security.
- Adopts modular design which has simple and clear operation.
- The software displays the device status information in real time and provides the function of online modification.
- A variety of filtering methods are added to satisfy the acquisition and analysis of different SNR data.
- Integrated meets regulatory requirements, audit trails, access management and electronic signatures.
Fraction Collector
- The compact structure is truly suitable for the preparation of complex components and can cooperate with the analysis liquid phase to preparate high purity substances precisely.
- Using rotary manipulator design to minimize space occupation.
- A variety of tube volume settings meet the needs of different collection volumes.
- Accurate piping design reduces the dead volume and collection error caused by diffusion.
- High precision bottle cutting technology and independent waste liquid channels make the bottle cutting process without drip leakage and pollution.
- Collection containers can be identified automatically, which prevent misplacing different types of collection containers.
- Manual/Automatic collection modes make it easy to be operated.
- Different collection containers are compatible. The maximum allowed collection containers: 120 pcs 13~15mm tubes.
- Multiple collection modes, such as time, threshold, slope etc., meet the requirements of different collection conditions.
Specifications
High Pressure Pump
| Parameters | Analytical Type | Semi-preparative Type | |
| Liquid delivery form | Double-piston series reciprocating pumps | Double-piston parallel reciprocating pump | |
| Flow rate | 0.001-10 mL/min,increment | 0.01-50 mL/min | 0.01-70 mL/min |
| Flow rate setting step | 0.001 mL/min | 0.01 mL/min | 0.01 mL/min |
| Flow rate precision | ≤ 0.06% | < 0.1% | < 0.1% |
| Maximum working pressure | 48 MPa | 30 MPa | 30 MPa |
| System protection | Soft start and stop (below the minimum pressure for 2min), adjustable Pmin and Pmax, automatically storage of user's data | ||
| GLP | Automatically record the usage of pump seal ring | ||
| Pump head material | Standard 316 L stainless steel, optional PEEK, titanium alloy, Hastelloy, PCTFE | ||
UV/Vis Dual Wavelength Detector
| Parameters | D2 | D2+W |
| Light source | D2 | D2+W |
| Wavelength range | 190-700 | 190-800 |
| Wavelength precision | 1 nm | |
| Wavelength accuracy | ±0.1 nm | |
| Linear range | 0-3 AU | |
| Baseline noise | ±0.5×10-5 AU(Dynamic, specifying conditions) | |
| Baseline drift | 1.0×10-4 AU/h(Dynamic, specifying conditions) | |
| GLP | Total lighting time, product serial number, delivery time | |
Column Oven
| Parameters | Analytical Type |
| Temperature control range | ambient +5 ~ 100℃ |
| Setting precision | 0.1℃ |
| Temperature accuracy | ±0.1℃ |
| Column | 2 pcs |
Autosampler
| Parameters | Analytical Type |
| Injection Mode | Full loop injection, partial loop fill injection, μL pickup injection |
| Sample bottle quality | 96 |
| Injection volume | 0-9999μL(1μL progressive) |
| Sample accuracy | 0.3%(Full loop injection) |
| Samples of residual | < 0.05% (Standard flush), normal <0.01% (Additional flush) |
Frequently Asked Questions
Q
What is the maximum working pressure of the High Pressure Pump in analytical type?
The analytical type High Pressure Pump supports a maximum working pressure of 48 MPa, while the semi-preparative types support up to 30 MPa. The system also features soft start/stop protection and adjustable Pmin/Pmax settings for safe operation.
Q
What injection volume range does the Autosampler support?
The Autosampler supports an injection volume range of 0.1 to 1000 μL (standard configuration: 0.1~100 μL). It offers three injection modes: full loop injection, partial loop fill injection, and μL pickup injection, with a sample accuracy of 0.3% for full loop injection.
Q
What wavelength range does the UV/Vis Dual Wavelength Detector cover?
The detector with a D2 light source covers a wavelength range of 190–700 nm, while the D2+W configuration extends coverage to 190–800 nm. The wavelength accuracy is ±0.1 nm with a precision of 1 nm, ensuring highly reliable detection results.
Q
Can the system be expanded to support additional detectors or modules?
Yes. The system features favorable expansibility. Optional modules include an autosampler, UV-Vis detector, differential detector, evaporative light-scattering detector, fluorescence detector, and fraction collector, allowing the system to be tailored to diverse analytical needs.
Q
What temperature range does the Column Oven support, and how accurate is the temperature control?
The Column Oven supports a temperature control range of ambient +5°C to 100°C, with a setting precision of 0.1°C and a temperature accuracy of ±0.1°C. It features overtemperature protection for safe and reliable operation and accommodates 2 chromatographic columns simultaneously.
Q
Does the Chromatography Workstation software support regulatory compliance requirements?
Yes. The Chromatography Workstation software is designed to meet regulatory requirements and includes features such as audit trails, access management, and electronic signatures. It also provides one-key data backup and restore using a database structure, ensuring full data integrity and security.