GCM-1522 Gas chromatography-mass spectrometry platform
GC
BIIC-Tech is a leading measurement company in China now,
dedicated to high-end analytical measuring instruments
Contact us

GCM-1522 Gas chromatography-mass spectrometry platform

    product detail

    Features

    1.Working condition

    Operating environmental temperature: 18-35

    Operating environmental humidity: ≤80%

    Operating voltage: 220 V (±10%), 50Hz (±2%)

    2.Single quadrupole mass spectrometer parameters

    High-precision all-metal quadrupole equipped with pre-quadrupole;

    Pre-quadrupole disassembly for cleaning to avoid contamination of the main quadrupole;

    No temperature control is required to ensure quality stability indicators;

    Optimizing ion energy technology;

    Main performance indicators

    Sensitivity: 1 pg, OFN S/N1500:1

    Quality range: 1.5-1250 amu

    Quality stability: ± 0.10 amu/48 hours

    Quality accuracy: ± 0.10 amu

    Maximum scanning speed: 20000 amu/s, with adjustable speed throughout the entire process

    Resolution: 0.4-4amu adjustable

    Dynamic range: 107

    Peak area reproducibility: < 2% RSD

    Scanning methods: full scan, selective ion monitoring, full scan and selective ion synchronous monitoring, alternating scanning.

    3.Ion source

    An inert ceramic ion source ensures that analytical substances will not adsorb on the ion source during long-term use, extending service life ;

    Dual filament design, alternating use to extend filament replacement time;

    Visual judgment of filament working status through the filament observation port;

     

    Type of ion source: Electron impact source (EI)

    Ion source configuration: Inert ceramic ion source, dual filament software switching

    Filament current: 0-500 μA

    Ionization energy: 5-100 eV

    Ion source temperature: 50℃-350℃

    Equipped with a filament observation window to visually judge the working status of the filament

    Interface temperature: 50-350℃

    4.Quality analyzer

    Quality analyzer: equipped with high-precision all metal quadrupole with pre quadrupole

    The quadrupole is optimized for temperature control, which can ensure quality stability indicators without the need for temperature control

    Pre quadrupole detachable and washable to avoid contamination of the main quadrupole

    The quadrupole has optimized ion energy technology, which optimizes the speed of ions passing through the quadrupole and improves signal quality

    5.Detector

    Long lifespan level 13 dispersed dynode electronic multiplier

    Equipped with a 10kV conversion dynode and a lens system for removing neutral noise

    6.Vacuum system

    Front stage pump, speed4 m³/h

    Configure a high-performance turbomolecular pumpspeed250 L/s

    Maximum allowable chromatographic column flow rate: 5 ml/min (He)

    Configured with a hot cathode ionization vacuum gauge, and the software can directly read high vacuum readings.

    7.Split/non split injector

    Maximum using temperature:450˚C

    Gas control mode: constant pressure, constant flow rate, program up/down pressure, program up/down flow, pulse injection

    Program boosting/current raising:10th order

    Pressure setting range:0-1035 kPa (0-150 psi)

    Maximum split ratio:9999.9:1

    Flow setting range: 0-200 mL/min (N2)

    Flow setting range: 0-1000 mL/min (H2)

    8.Column oven

    Operating temperature range: room temperature: +4˚C to 450˚C

    Temperature Setting Accuracy:0.1˚C

    Temperature control accuracy:0.01˚C

    Temperature Stability: 0.5%

    Temperature uniformity: 2.5%

    Environmental sensitivity: When the ambient temperature changes by 1˚C, better than 0.01℃

    Heating Rate::100˚C /min

    Programmed Heating Repeatability: 1%

    Programmed Heating Order: 32

    Cooling Time (from 450℃to 50℃): 4 min

    Maximum Running Time: 9999.999 min

     

    • Wide temperature RF power supply can better adapt to various laboratory environments, and instrument performance is more stable;
    • High precision all metal quadrupole, ensuring good resolution;
    • Quadrupole mass analyzer with pre quadrupole, quadrupole has stronger anti-pollution ability;
    • Electronic multiplier with high-energy conversion dynode, ensuring excellent sensitivity;
    • Adopting high-performance turbo molecular pump, with high pumping speed and stable operation, ensuring long-term high vacuum environment for mass spectrometry;
    • High temperature inert ion source has high ionization efficiency, reduces pollution, and is equipped with dual filaments, providing twice the usage time;
    • Configured with automatic sampler, blow trap, thermal analyzer, headspace sampler to achieve sample analysis of different states;