China GCM-1522 Gas Chromatography-Mass Spectrometry Platform from Leading Suppliers and Factory
Hot Products
BIIC-Tech is a leading measurement company in China now,
dedicated to high-end analytical measuring instruments
Contact us

China GCM-1522 Gas Chromatography-Mass Spectrometry Platform from Leading Suppliers and Factory

Discover our top-quality products manufactured in China, where we collaborate with reliable suppliers to ensure superior craftsmanship and exceptional performance. Our factory employs state-of-the-art technology and skilled artisans to deliver items that meet the highest standards. By sourcing directly from our China-based factory, we provide unbeatable value and efficiency, allowing you to access a wide range of products tailored to your needs. Choose us as your trusted supplier and experience the excellence that comes from our dedication to quality and innovation in every item we produce

    Features
    1

    Working Condition

    Operating Environmental Temperature 18–35 ℃
    Operating Environmental Humidity ≤ 80%
    Operating Voltage 220 V (±10%), 50 Hz (±2%)
    2

    Single Quadrupole Mass Spectrometer Parameters

    ✦ High-precision all-metal quadrupole equipped with pre-quadrupole

    ✦ Pre-quadrupole disassembly for cleaning to avoid contamination of the main quadrupole

    ✦ No temperature control required to ensure quality stability indicators

    ✦ Optimizing ion energy technology

    Sensitivity 1 pg, OFN S/N ≥ 1500:1
    Quality Range 1.5–1250 amu
    Quality Stability ± 0.10 amu / 48 hours
    Quality Accuracy ± 0.10 amu
    Maximum Scanning Speed 20000 amu/s, adjustable throughout the entire process
    Resolution 0.4–4 amu adjustable
    Dynamic Range 107
    Peak Area Reproducibility < 2% RSD
    Scanning Methods Full scan, selective ion monitoring, full scan and selective ion synchronous monitoring, alternating scanning
    3

    Ion Source

    ✦ Inert ceramic ion source ensures analytical substances will not adsorb on the ion source during long-term use, extending service life

    ✦ Dual filament design, alternating use to extend filament replacement time

    ✦ Visual judgment of filament working status through the filament observation port

    Type of Ion Source Electron Impact Source (EI)
    Ion Source Configuration Inert ceramic ion source, dual filament software switching
    Filament Current 0–500 μA
    Ionization Energy 5–100 eV
    Ion Source Temperature 50℃–350℃
    Filament Observation Window Equipped — visually judges working status of filament
    Interface Temperature 50–350℃
    4

    Quality Analyzer

    ✦ Equipped with high-precision all-metal quadrupole with pre-quadrupole

    ✦ Optimized temperature control ensures quality stability indicators without the need for temperature control

    ✦ Pre-quadrupole detachable and washable to avoid contamination of the main quadrupole

    ✦ Optimized ion energy technology improves the speed of ions passing through the quadrupole and enhances signal quality

    5

    Detector

    ✦ Long lifespan level 13 dispersed dynode electronic multiplier

    ✦ Equipped with a 10 kV conversion dynode and a lens system for removing neutral noise

    6

    Vacuum System

    Front Stage Pump Speed ≥ 4 m³/h
    Turbomolecular Pump Speed ≥ 250 L/s (high-performance)
    Maximum Allowable Column Flow Rate 5 ml/min (He)
    Vacuum Gauge Hot cathode ionization vacuum gauge; software can directly read high vacuum readings
    7

    Split / Non-Split Injector

    Maximum Using Temperature 450 ˚C
    Gas Control Mode Constant pressure, constant flow rate, program up/down pressure, program up/down flow, pulse injection
    Program Boosting / Current Raising 10th order
    Pressure Setting Range 0–1035 kPa (0–150 psi)
    Maximum Split Ratio 9999.9:1
    Flow Setting Range (N₂) 0–200 mL/min
    Flow Setting Range (H₂) 0–1000 mL/min
    8

    Column Oven

    Operating Temperature Range Room temperature +4 ˚C to 450 ˚C
    Temperature Setting Accuracy 0.1 ˚C
    Temperature Control Accuracy 0.01 ˚C
    Temperature Stability ≤ 0.5%
    Temperature Uniformity ≤ 2.5%
    Environmental Sensitivity When ambient temperature changes by 1 ˚C, better than 0.01℃
    Heating Rate ≥ 100 ˚C/min
    Programmed Heating Repeatability ≤ 1%
    Programmed Heating Order 32
    Cooling Time (450℃ to 50℃) ≤ 4 min
    Maximum Running Time 9999.999 min

    Key Advantages

    • Wide temperature RF power supply can better adapt to various laboratory environments, and instrument performance is more stable
    • High-precision all-metal quadrupole, ensuring good resolution
    • Quadrupole mass analyzer with pre-quadrupole provides stronger anti-pollution ability
    • Electronic multiplier with high-energy conversion dynode, ensuring excellent sensitivity
    • High-performance turbo molecular pump with high pumping speed and stable operation, ensuring long-term high vacuum environment for mass spectrometry
    • High-temperature inert ion source has high ionization efficiency, reduces pollution, and is equipped with dual filaments, providing twice the usage time
    • Configured with automatic sampler, blow trap, thermal analyzer, headspace sampler to achieve sample analysis of different states
    Frequently Asked Questions
    Q What is the sensitivity of the single quadrupole mass spectrometer?
    The instrument achieves a sensitivity of 1 pg with an OFN S/N ratio of ≥ 1500:1, ensuring reliable detection of trace-level analytes in complex sample matrices.
    Q Why does the ion source use an inert ceramic design instead of a metal ion source?
    The inert ceramic ion source prevents analytical substances from adsorbing onto its surface during long-term use. This significantly reduces contamination risk, extends the service life of the ion source, and maintains more consistent analytical performance over time.
    Q What is the purpose of the pre-quadrupole in the quality analyzer?
    The pre-quadrupole acts as a protective filter for the main quadrupole. It is detachable and washable, preventing contamination from reaching the main quadrupole and thereby extending the instrument's operational life while maintaining high analytical accuracy.
    Q What scanning modes are supported by this GC-MS system?
    The system supports four scanning modes: full scan (SCAN), selective ion monitoring (SIM), full scan and selective ion synchronous monitoring (SCAN/SIM), and alternating scanning — providing maximum flexibility for both qualitative and quantitative analysis workflows.
    Q What are the operating environmental requirements for the instrument?
    The instrument requires an operating temperature between 18–35℃ and a relative humidity of ≤ 80%. The power supply must be 220 V (±10%) at 50 Hz (±2%) to ensure stable and safe operation.
    Q Can this GC-MS system be used with different types of sample introduction accessories?
    Yes. The system is compatible with a range of sample introduction accessories, including an automatic sampler, blow trap, thermal analyzer, and headspace sampler. This versatility allows it to handle samples in various physical states — liquid, solid, and gaseous — making it suitable for a wide range of analytical applications.